Wyślij wiadomość
Dom ProduktyAmortyzator regulacji głośności

Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution

Orzecznictwo
Chiny DONGGUAN LIHONG CLEANROOM CO., LTD Certyfikaty
Chiny DONGGUAN LIHONG CLEANROOM CO., LTD Certyfikaty
Opinie klientów
ZHISHENG company provide high quality air shower room and good sevice. Miss Rita Guo will provide the drawing and details to us to confirm at order.

—— Subramaniam Muthusamy

Miss Rita Guo is a nice person, she is very patient to explain anything which we are confused, besides, she is professional on air shower.

—— ORAI CO.LTD

Im Online Czat teraz

Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution

Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution
Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution

Duży Obraz :  Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution

Szczegóły Produktu:
Place of Origin: Guangdong, China (Mainland)
Nazwa handlowa: Zhisheng
Orzecznictwo: ISO9001
Model Number: ZS-YF
Zapłata:
Minimum Order Quantity: 20 sets
Packaging Details: plywood case
Delivery Time: about 15 days upon receipt of deposit
Supply Ability: 200 sets per month

Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution

Opis
Material: galvanized for base Type: round air volume damper
Control: Manual Color: blue
Size: customar's cize Application: correct air flow distribution
High Light:

air control damper

,

air duct damper

 

 

Galvanized Sheet FHW - 0 Gravity - Operated Volume Fire Air Damper

 

Description : 

 

Main Components include Valve body, blade, axle, axle bushing, actuator.


• Valve body and blade are made from fine galvanized sheet with excellent surface, perfect non-corrosibility and long time product usage.


• The damper is Installed on air hose of the air ventilation system air hose to regulate

the airflow and control velocity.


•There is no need refueling to guarantee permanent lubrication that both blade and connecting axle of rotation adopt to metallurgy axle sheet with oiled copper powder.


•The damper is designed with V-shape anti-skip structure between the blade and axle to ensure the blades not slip and tight on high speed situation.


•It is usually open, and the fusing temperature of the fusible film is 70℃.


•The valve can be open and closed manually, and reset manually after acting.)


•Can output valve closed signal.

 

Galvanized Sheet Volume Control Damper For Correct Air Flow Distribution 0

 

Szczegóły kontaktu
DONGGUAN LIHONG CLEANROOM CO., LTD

Osoba kontaktowa: Miss. Rita Guo

Tel: 86-13712072567

Faks: 86-769-22037328

Wyślij zapytanie bezpośrednio do nas (0 / 3000)